Simultaneous RP-HPLC Determination of Drotaverine Hydrochloride and Mefenamic Acid in Their Combined Tablet Dosage Form

 

R.S. Sakhare*, A.B. Roge, R.L. Bakal, A.D. Dewani, M.D. Kshirsagar and A.V. Chandewar

P. Wadhwani College of Pharmacy, Yavatmal-445 001 (M.S.)

*Corresponding Author E-mail: r.s.sahkare@gmail.com

 

ABSTRACT:

A simple, precise, accurate, rapid and reproducible reverse phase high performance liquid chromatographic procedure was developed for simultaneous determination of Drotaverine HCL and Mefenamic Acid in tablet dosage form at a single wavelength. The mobile phase used was a combination of Methanol: Acetonitrile: KH2PO4 Buffer (10 mM):  (40: 40: 20) pH 3.5. The detection of the combined dosage form was carried out at 240 nm and flow rate was set to 1ml/min. Linearity was obtained in the concentration range of 3 to 30 µg/ml of Drotaverine HCL and 6 to 33 µg/ml of Mefenamic Acid with correlation coefficients of 0.9998 and 0.9999, respectively. The results of the analysis were validated statistically and recovery studies confirmed the accuracy of the proposed method.

 

KEYWORDS: Drotaverine HCL, Mefenamic Acid , RP-HPLC, Simultaneous estimation.

 


 

INTRODUCTION:

Drotaverine, 1-(3,4-diethoxybenzylidene)-6,7-diethoxy-1,2,3,4-tetrahydroisoquinoline, is an antispasmodic drug, structurally related to papaverine. It is a selective inhibitor of phosphodiesterose 4 and has no anticholinergic effect. It is used in treating renal colic and has also been used to accelerate labor1-4 Few methods have been reported for the determination of drotaverine in dosage forms and in biological fluids including, high performance liquid chromatography (HPLC)5–8 thin layer densitometric9 spectrophotometric9–12 differential spectrophotometric13,14 computer-aided spectrophotometric15 and potentiometric16–19 methods. Also Fulop20 proposed a polarographic method for determination of drotaverine in 1M H2SO4 at −420 mV in the range 4–80 μg and recently Ziyatdinova21 proposed voltammetric method for determination of the drug by oxidation at a graphite electrode in 0.1 M H2SO4 at 1.05 and 1.28 V, but up to now nothing has been published concerning the adsorptive cathodic stripping voltammetric determination of this drug using HMDE.

 

Mefenamic acid (MF), N-(2,3-Xylyl) anthranilic acid, is a non-steroidal drug. It has analgesic and antipyretic properties. Mefenamic acid is used in musculoskeletal and joint disorders such as osteoarthritis and rheumatoid arthritis22.

 

The compound is almost insoluble in water but is readily soluble in organic solvents such as dioxane, alcohols and dimethyl formamide23.

 

MEF is official in BP and USP NF24, 25. Literature survey revealed that HPLC26,27  methods have been reported for the estimation of Drotaverine Hcl and Mefenamic Acid individually and with other drugs in pharmaceutical dosage forms. Literature review revealed that no HPLC method is yet reported for the simultaneous estimation of the DRO and MEF in combined tablet dosage form at single wavelength. Therefore, it was thought worthwhile to develop simple, precise, accurate reverse phase HPLC method for simultaneous estimation of DRO and MEF in combined tablet dosage form.

 

MATERIAL AND METHOD:

Pharmaceutical grade DRO and MEF were supplied as a gift sample by Alkem Laboratory, Mumbai, (Maharashtra), India. The tablet dosage form (Drofem, Batch No. MAC 9094, Mfg. Dt. 09/09 and Exp. Dt. 08/2011) was procured from the local market (Label claim: 80 mg DRO and 250 mg MEF) marketed by FDC Limited, Aurangabad. All chemicals used were of HPLC grade and were purchased from Samar Chemicals, Nagpur, India.


Instrument:
LC system (Thermo Separation Product Quaternary Gradient HPLC pump Spectra System P4000) used consist of pump with universal loop injector (Rheodyne 9725 I) of injection capacity 20 ul. Detector consists of Variable UV-VIS detector of Spectra System U V 1000 with Data Ace Software; the reversed phase column used was Machinery. Nagel (M N) EC 250/4.6 Nucleosil 100-5 C18, at ambient temperature. Among the several mobile phases used for the simultaneous estimation of DRO and MEF, Methanol: Acetonitrile: KH2PO4 Buffer (10 mM) (40: 40: 20) pH 3.5 was found to be most suitable and was filtered through 0.2 micron membrane filter.

 

PREPARATION OF MOBILE PHASE:

Potassium dihydrogen orthophosphate was weighed (0.272g) & dissolved in 200 ml water.

 

This solution was mixed with 400 ml methanol & finally 400 ml of acetonitrile was added to the above prepared solution & mixed well. pH was adjusted to 3.5. The solution was sonicated for 10 minute and filtered using membrane filter.

 

PREPARATION OF SOLUTIONS:

DRO standard stock solution:

Accurately weighed quantity 2.5 mg of DRO was dissolved in methanol and volume was made up to 25 ml mark (100µg/ml). The stock standard solution was diluted further with mobile phase to get various concentrations i.e. 3-30 µg/ml.

 

MEF standard stock solution:

Accurately weighed quantity 2.5 mg of MEF was dissolved in methanol and volume was made up to 25 ml mark (100 µg/ml). The stock standard solution was diluted further with mobile phase to get various concentrations i.e. 6-33 µg/ml.

 

A volume of 20 µl of each standard after filtration by 0.2-micron membrane filter was injected into column and peak area was recorded. Calibration curves were constructed by plotting the peak area versus the corresponding drug concentration. The slope and co-relation coefficients were determined [Table 1].

 

TABLE NO. 1: Regression analysis of the calibration curve for the proposed method

Sr. No.

Parameter

Value

DRO

MEF

1

Calibrations Range (µg/ml)

3-30

6-33

2

Slope (m)

48.001

52.277

3

Intercept (c)

0.1737

0.3808

4

Correlation Coefficient (r2)

0.999

0.999

 

Estimation of drugs in commercial tablet formulation:

Twenty tablets were weighed. The average weight determined. It was finely powdered and mixed thoroughly. Accurately weighed tablet powder equivalent to 8 mg of DRO was transferred in a 100 ml volumetric flask and methanol was added. It was shaken vigorously for 5 to 10 minutes. Later the volume was made up to mark with Mobile phase to get concentration 8mg/ml of DRO and 25 mg/ml of MEF. The solution was filtered through Whatman filter paper No.42.

 

Equal volume (20ml) of standard and sample solutions were injected separately after equilibrium of stationary phase. The chromatograms were recorded and the response i.e. peak area of major peaks were measured. The content of DRO and MEF was calculated by comparing a sample peak with that of standard.

 

VALIDATION:

The method was validated for linearity, range, accuracy, precision, specificity and Ruggedness by following procedures. The accuracy of the method was determined by calculating recovery of DRO and MEF by method of standard addition. Known amount of DRO (0.8, 1.6, 2.4 µg/ml) and MEF (2.5, 5, 7.5 µg/ml) were added to a pre quantified sample solution, and the amount of DRO and MEF were estimated by measuring the peak area ratios and by fitting these values to the straight-line equation of calibration curve.


The intraday and inter day precision study of DRO and MEF were carried out by estimating the corresponding responses 3 times on the same day and on 3 different days for the period of 1 week for the same sample solution . Repeatability studies were carried out by estimating response of 3 different test solution. The linearity of the method was determined by
accurately weighing quantities of tablet powder equivalent to 80, 90, 100, 110, 120 % of label claim and doing dilutions appropriately to obtain a concentration in the range of 80-120% of the test concentration and peak area were recorded at 240 nm.

 

FIG. NO. 1: Overlain spectra of DRO and MEF

 

TABLE NO. 2: Summary of validation parameters for the proposed method

Sr. No.

Parameter

Value

DRO

MEF

1

Specificity

No interference was found to be w.r.t.

excipients, impurities

2

Linearity Range

80-120 %

80-120 %

3

Precision

0.7549

0.5000

4

Accuracy

99.89

99.87

5

Intraday

0.4725

0.4003

6

Interday

0.4752

0.3371

 


 

TABLE NO. 3 :Result of System Suitability Study

Sr. No

Peak  area

Retention Time

Asymmetry

No .of theoretical Plates

Resolution

DRO

MEF

DRO

MEF

DRO

ME

DRO

MEF

1

384.384

1315.11

4.123

6.935

2.001

1.721

4187.255

1315.11

9.485

2

428.086

1361.23

4.122

6.936

2.000

1.720

4184.21

1361.23

9.450

3

428.615

1367.51

4.123

6.935

1.998

1.719

4164.609

1367.51

9.475

4

426.662

1368.20

4.122

6.935

2.001

1.720

4148.423

1368.20

9.480

5

420.598

1364.12

4.123

6.936

2.001

1.721

4180.259

1364.12

9.465

mean

417.669

1355.23

4.122

6.935

2.000

1.720

4172.9512

1355.23

9.471

+ S.D

18.8790

22.604

0.0008

0.00070

0.00132

0.0008

16.2479

22.6049

0.01387

C.V

4.5200

1.667

0.0210

0.01019

0.0661

0.0503

0.3893

1.6679

0.1464

 

TABLE NO. 4: Results and statistical data for estimation of DRO and MEF in Marketed formulation.

Brand name: DROFEM Avg.wt = 58.64 mg

Sr. no.

Weight of std.(mg)

Weight of sample

(mg)

Peak area of std

Peak area of sample

% Label claim

DRO

MEF

DRO

MEF

DRO

MEF

DRO

MEF

1.

8

25

58.54

383.834

1307.305

383.60

1312.394

100.14

100.59

2.

58.60

383.41

1300.769

99.89

99.50

3.

58.62

379.57

1303.253

98.89

99.69

 

Mean

99.64

99.92

 

±S.D.

0.661437

0.582322

 

C.V.

0.663828

0.582789

 

 


 

 

 

 

 

 

 

Commonly used excipients that include, dibasic calcium phosphate dihydrate, microcrystalline cellulose, magnesium stearate and polyethylene glycol were spiked into a preweighed quantity of drug. The chromatogram was taken by appropriate dilutions and the quantities of drugs were determined. Calibration curves were prepared using concentrations in the range of 3-30 µg/ml and 6-33 µg/ml for DRO and MEF respectively. The standard deviation of y-intercepts of regression line was determined and kept in following equation for the determination of detection limit and quantitation limit. Detection limit = 3.3s/s; Quantitation limit = 10s/s, where s is the standard deviation of y-intercepts of regression lines and s is the slope of the calibration curve. UV overlain spectra of both DRO and MEF showed that both the drugs absorbs appreciably at 240 nm, So 240 nm was selected as the detection wavelength in liquid chromatography [Figure 1]. Optimization of mobile phase was performed based on resolution, asymmetric factor and peak area obtained. Different mobile phases were tried but satisfactory separation, well resolved and good symmetrical peaks were obtained with the mobile phase Methanol: Acetonitrile: KH2PO4 Buffer (10 mM) (40: 40: 20) pH 3.5. The retention time of DRO was found to be 4.123 min and that of MEF was found to be 6.973 min, respectively [Figure 2]. Resolution between DRO and MEF was found to be 9.471, which indicate good separation of both the compounds. The asymmetric factor for DRO was 2.000.

 

The asymmetric factor for MEF was 1.720. The calibration curve for DRO was obtained by plotting the peak area ratio versus the concentration of DRO over the range of 3-30 µg/ml, and it was found to be linear with r 2 = 0.999. The calibration curve for MEF was obtained by plotting the peak area ratio versus the concentration of MEF over the range of 6-33µg/ml, and it was found to be linear with r 2 = 0.9999. The data of regression analysis of the calibration curves are shown in [Table 1]. The validation parameters are summarized in [Table 2]. The recovery of DRO and MEF was found to be in the range of 99.5-100.3 %. The system suitability test parameters are shown in [Table 3]. The proposed liquid chromatographic method was applied for the determination of DRO and MEF in tablet formulations. The result for DRO and MEF were comparable with the corresponding labeled amount [Table 4].

 

FIG. NO. 2: Chromatogram obtained by tablet formulation of DRO and MEF

Showing retention time for DRO–4.123min. and MEF – 6.973 min..


Proposed study describes new LC method for the estimation of DRO in tablet formulations. The method was validated and found to be simple, sensitive, accurate and precise. Percentage of recovery shows that the method is free from interference of the excipients used in the formulation. Therefore the proposed method can be used for routine analysis for estimation of DRO and MEF in its tablet formulations.

ACKNOWLEDGEMENTS:

The authors are thankful to Prof. (Dr.) A.V. Chandewar, Principal, P. Wadhwani College of Pharmacy, Yavatmal, for his valuable guidance and advice. The authors are grateful to Alkem Laboratories India, Mumbai for providing gift sample of Drotaverine Hydrochloride and Mefenamic Acid respectively.

 

REFERENCES

1.       S.C. Sweetman (Ed.), Marttindale. The Complete Drug Reference, 34th ed., Pharmaceutical Press, London, 2005, p. 1683.

2.       M.C. Griffiths, USAN and the USP Dictionary of Drug Names, United States Pharmacopeial Convention, Inc.,12601 Twinbrook Parkway, Rockville, MD,1984, p.175.

3.       I. Romics, D.L. Molnar, G. Timberg, The effect of drotaverine hydrochloride acute colicky pain caused by renal and ureleric stones, BJU Int. 92 (2003) 92–96.

4.       K.C. Singh, P. Jain, N. Goel, A. Saxena, Drotaverine hydrochloride for Augmentation of labor, Int. J. Gynaecol. Obstet. 84 (2004) 17–22

5.       O.O. Bolaji, C.O. Onyeji, F.O. Ogungbamila, F.A. Ogunbona, High performance liquid chromatographic method for the determination of drotaverine in human plasma and urine, J. Chromatogr. Biomed. Appl. 622 (1993) 93–97.

6.       J.K. Lalla, M.U. Shah, M.B. Jain, A.H. Sharma, Modified high performance liquid chromatographic method for analysis of drotaverine in human plasma, J. Pharm. Biomed. Anal. 11 (1993) 385–388.

7.       J. Mezei, S. Kuttel, P. Szentmiklosi, S.Marten, I. Racz, Newmethod for high Performance liquid chromatographic determination of drotaverine in plasma, J. Pharm. Sci. 73 (1984) 1489–1991.

8.       E.H. Girgis, Ion pair reversed phase liquid chromatographic identification and quantitation of papaverine congeners, J. Pharm. Sci. 82 (1993) 503–505.

9.       H.E. Abdellatef, M.M. Ayad, S.M. Soliman, N.F. Youssef, Spetrophotometric and spectrodensitometric determination of paracetamol and drotaverine HCl in combination, Spectrochim. Acta A Mol. Biomed. Spectrosc. 66 (2007) 1147–1151.

10.     F.H. Metwally, Simultaneous determination of nifuroxazide and drotaverine hydrochloride in pharmaceutical preparations by bivariate and multivariate spectral analysis, Spectrochim. Acta A Mol. Biomed. Spectrosc. 69 (2008) 343– 349.

11.     A.S. Amin, R. El Sheikh, F. Zahran, A.A. Gouda, Simultaneous determination of nifuroxazide and drotaverine hydrochloride in pharmaceutical preparations by bivariate and multivariate spectral Aalysis, Spectrochim. Acta A Mol. Biomed. Spectrosc. 67 (2007) 1088–1093.

12.     R. El Shiekh, F. Zahran, A.A. Gouda, Spectrophotometric determination of some anti-tussive and anti-spasmodic drugs through ion pair complex formation with thiocyanate and cobalt (II) molybdenum (V), Spectrochim. Acta A 66 (2007) 1279–1287.

13.     H.G. Daabees, Selective differential spectrophotometric methods for Determination of niclosamide and drotaverine hydrochloride, Anal. Lett. 33 (2000) 639–656.

14.     V.A. Knaub, V.A. Kartashov, Application of differential spectrophotometry to determination of Nospa (drotaverine) in biological materials, Farmatsiya 38 (1989)46–49.

15.     J. Geher, E. Szabo, Computer aided spectrophotometric determination of multi component drugs, J. Pharm. Biomed. Anal. 6 (1988) 757–764.

16.     Y.S. El-Saharty, F.H. Metwaly, M. Refaat, S.Z. El Khateeb, Application of new membrane selective electrodes for the determination of drotaverine hydrochloride in tablets and plasma, J. Pharm. Biomed. Anal. 41 (2006) 720– 724.

17.     H. Ibrahim, Y.M. Issa, H.M. Abu-Shawish, Improving the detection limits of antispasmodic drugs electrodes by using modified membrane sensors with inner solid contact, J. Pharm. Biomed. Anal. 44 (2007) 8–15.

18.     H. Ibrahim, Y.M. Issa, H.M. Abu-Shawish, Potentiometric flow injection analysis of drotaverine hydrochloride in pharmaceutical preparations, Anal. Lett. 38 (2005) 111–132.

19.     Y.M. Issa, H. Ibrahim, H.M. Abu-Shawish, Carbon paste electrode for the potentiometric flow injection analysis of drotaverine hydrochloride in serum and urine, Microchim. Acta 150 (2005) 47–54.

20.     M. Fulop, K. Kaloy, A. Toth, Electrochemical investigation of drotaverine. I Square wave polarographic measurement, Magy-Kem-Foly 92 (1986) 468–473.

21.     G. Ziyatdinova, A. Samigullin, G. Budnikov, Voltammetric determination of papaverine and drotaverine, J. Anal. Chem. 62 (2007) 773–776.

22.     J.E.F. Reynolds, K. Parfitt, A.V. Parsons, S.C. Sweetman, Martindale: The Extra Pharmacopoeia, 30th ed., Pharmaceutical Press, London, 1993, p. 15, 23.

23.     A. S. Griogor’eva and N. F. Konakhovich, Zh. Neorg. Khim. 27, 1209-1215 (1982)

24.     British Pharmacopoeia, Vol.II, 2008

25.     United State Pharmacopoeia, Vol.III, 2009, 3804

 

 

 

Received on 21.05.2010        Modified on 13.06.2010

Accepted on 24.06.2010        © AJRC All right reserved

Asian J. Research Chem. 3(4): Oct. - Dec. 2010; Page 986-989